A high-pass filter removes the frequencies below a cutoff point and lets everything above it through, and a low-pass filter does the reverse, keeping the lows and removing the highs. Both are standard on most parametric EQs. Vocal Cut's free audio equalizer uses gentler shelves instead; its true high-pass filter is in the mastering tool. For the wider picture of what EQ does, see What Is EQ (Equalization)?.
The naming trips up nearly everyone, because it describes what the filter keeps, not what it removes.
Some EQs call them "low cut" and "high cut" instead, naming the removal. Same filters.
The cutoff frequency is where the filter starts to bite. It isn't a brick wall: by the usual convention the signal at the cutoff is already about 3 dB down, and the cut deepens gradually from there. If frequency numbers feel abstract, What Are Audio Frequencies? maps them to what you hear.
How fast it deepens is the slope, measured in decibels per octave (dB/octave). An octave is a doubling or halving of frequency, so 100 Hz down to 50 Hz is one octave. Common slopes are 6, 12, 18, 24 and 48 dB/octave; steeper ones cut harder and closer to the cutoff. A 12 dB/octave high-pass set to 100 Hz leaves 200 Hz practically untouched, is about 3 dB down at 100 Hz, roughly 12 dB down at 50 Hz and roughly 24 dB down at 25 Hz.
It keeps going like that and never levels off. Remember that, because it's what separates a pass filter from a shelf.
The high-pass and low-pass controls in Vocal Cut's tools each use one of the browser's standard Web Audio filters (the BiquadFilterNode), whose high-pass and low-pass shapes are second-order, a 12 dB/octave slope. That's steep enough to clear out rumble without the abrupt edge of a 48 dB/octave filter.
Many filters also have a resonance or Q control. Raising it adds a bump right at the cutoff, boosting a narrow slice before the cut takes over. For cleanup you want little or none, since the bump colors the sound. Resonance is what gives a synth filter sweep its vocal, "wah"-like character, which makes it a sound-design tool rather than a corrective one.
Use a high-pass when there's low-frequency energy that doesn't belong to the sound you care about:
These are widely used starting points, not rules. Sweep the cutoff up until the sound starts to thin out, then back it off a little.
| Source | Common starting point for the cutoff |
|---|---|
| Spoken voice, podcast, voiceover | around 80–100 Hz |
| Sung vocal | around 80–100 Hz, lower for deep voices |
| Acoustic guitar | around 80–100 Hz |
| Kick drum, bass guitar | low or none, perhaps 30–40 Hz |
| Full mix or master | around 20–30 Hz, to clear sub-audible rumble |
That last row makes sense once you know where hearing stops: The Audible Frequency Range (20Hz-20kHz) explains why energy down there is felt more than heard yet still eats headroom.
A low-pass does two jobs well. The first is taming a harsh or fizzy top end that sits above the useful part of a sound. It won't remove hiss, though: hiss is spread across the whole spectrum, so a low-pass only softens it, and set too low it just makes everything dull. How to Remove Hiss from Audio covers the proper fix.
The second is effects:
To hear one in action, open the Noise Generator. Its Soften highs slider (a low-pass cutoff) runs from 300 Hz to 20 kHz (20 kHz is off). Start white noise, drag the slider down, and the hiss darkens into a muffled roar as the highs disappear.
On a graph a shelf and a pass filter look alike, but they behave differently. A shelf turns a region down by a fixed amount and then flattens out, so a −12 dB low shelf leaves the deep lows about 12 dB quieter but still there. A pass filter keeps cutting with every octave, so the far end is effectively gone.
Vocal Cut's Equalizer is a 6-band graphic EQ: a low shelf at 80 Hz, peaking bands at 240 Hz, 750 Hz, 2.2 kHz and 6 kHz, and a high shelf at 12 kHz, each ±12 dB in 1 dB steps. Pulling the 80 Hz shelf down gives you less boom, which is often the goal, but it can't remove deep rumble entirely the way a high-pass can.
On a parametric audio equalizer, the outer bands can usually switch between shelf and pass shapes; Parametric vs Graphic EQ: The Difference explains what else that control buys you. Shelves tend to suit broad tonal moves. Pass filters suit junk that sits entirely below or above the sound.
A band-pass is a high-pass and a low-pass stacked, so only the band between them survives. The telephone effect above is one.
Filters can also split audio rather than remove anything. Vocal Cut's Audio Master does this in its multiband compressor: low-pass and high-pass crossover filters at 200 Hz and 4 kHz divide the track into lows, mids and highs, each band is compressed separately, and the three are summed back. What Is Multiband Compression? explains why.
The Audio Master has a Rumble filter, a true high-pass adjustable from 20 to 100 Hz in 5 Hz steps (30 Hz by default). The Audio Enhancer applies a fixed high-pass automatically, 80 Hz in voice mode and 30 Hz in music mode, with no adjustment. The Noise Generator has the low-pass, and the Equalizer has the shelves. All of them run in your browser, so your audio never leaves your device.
For hands-on EQ moves beyond filters, read the Audio Equalizer Guide: How to EQ for Clarity or How to EQ a Vocal in Your Browser. More concepts like this are in the explainers section.
What does a high-pass filter do? A high-pass filter lets frequencies above a chosen cutoff pass through and progressively cuts everything below it. It's used to remove low-frequency problems such as rumble, mic handling noise, wind buffeting and plosive thumps. The name describes what it keeps, so a high-pass filter is the same thing many EQs label a low cut.
What does a low-pass filter do? A low-pass filter lets frequencies below a chosen cutoff pass through and progressively cuts everything above it. It's used to soften harsh or fizzy treble and for effects such as muffled, underwater or telephone-style sounds. Many EQs label it a high cut.
What does 12 dB per octave mean on a filter? It's the filter's slope, meaning how quickly it cuts past the cutoff. An octave is a doubling or halving of frequency, so a 12 dB per octave high-pass set to 100 Hz is about 12 dB down at 50 Hz and about 24 dB down at 25 Hz. Steeper slopes such as 24 or 48 dB per octave cut harder.
What frequency should I set a high-pass filter to on vocals? A common starting point for spoken or sung vocals is around 80 to 100 Hz, a little lower for very deep voices. Treat it as a place to start, not a rule: sweep the cutoff up until the voice begins to sound thin, then back it off slightly so you remove rumble without losing body.
What is the difference between a high-pass filter and a low shelf? A low shelf reduces the low frequencies by a fixed amount and then flattens out, so a -12 dB shelf leaves the lows about 12 dB quieter but still present. A high-pass filter keeps cutting further with every octave below its cutoff, so deep rumble is effectively removed. Use a shelf for gentle shaping and a high-pass to clear unwanted low end.